CDT Carbon Dioxide/Temperature Transmitter

Loại sản phẩm: Đo nồng độ khí CO2

Mã sản phẩm: CDT-5W44-LCD

Nhà cung cấp: ANS Vietnam

Xuất Xứ: 100% USA Origin

Hãng sản xuất: Dwyer Instruments

Giá : Vui lòng liên hệ

Series CDT Carbon Dioxide/Temperature Transmitter

NDIR CO2 Sensor, Universal Outputs, Optional Relay

Bookmark and Share

The SERIES CDT Carbon Dioxide and Temperature Transmitters accurately monitor the CO2 concentration and temperature in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength nondispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. The single beam dual wavelength sensor technology provides the highest level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. In order to achieve a higher level of accuracy, the Series CDT includes digital barometric pressure adjustment and the ability to field-calibrate the sensor. For applications that require visual indication, the wall mount configurations of the Series CDT can be ordered with an integral LCD display. Push buttons are standard on all configurations of the transmitters for access to the menu structure, but wall mount configurations can be ordered without the buttons. To prevent tampering, the action of the buttons can be locked out using an internal dip switch selection.

*For buildings occupied 24 hours per day, it is recommended that calibration be verified every 6 to 12 months depending on application.

Single beam dual-wavelength sensor advantages:

  • Automatically corrects for aging effects in occupied and unoccupied buildings
    • Perfect for hospitals and manufacturing plants that are occupied 24 hours per day
  • Measures actual unfiltered light intensity directly
    • Eliminates error from incorrect assumptions of gas concentration in theoretical logic assumption methods

 

Product Applications

  • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
  • LEED® certification
Model Description
CDT-2D40 Carbon Dioxide Transmitter, duct mount, 2000 ppm CO2 range, 4 to 20 mA / 0 to (5 or 10) VDC CO2 output.
CDT-2D44 Carbon Dioxide Transmitter, duct mount, 2000 ppm CO2 range, 4 to 20 mA / 0 to (5 or 10) VDC CO2 output & temperature output.
CDT-2D4A Carbon Dioxide Transmitter, duct mount, 2000 ppm, CO2 transmitter with current/voltage CO2 outputs and 10K Ohm Type III thermistor temperature output.
CDT-2D4B Carbon Dioxide Transmitter, duct mount, 2000 ppm, CO2 transmitter with current/voltage CO2 outputs and 10K Ohm Type II thermistor temperature output.
CDT-2D4D Carbon Dioxide Transmitter, duct mount, 2000 ppm, CO2 transmitter with current/voltage CO2 outputs and PT100 Ohm RTD temperature output.
CDT-2D4E Carbon Dioxide Transmitter, duct mount, 2000 ppm, CO2 transmitter with current/voltage CO2 outputs and PT1000 RTD temperature output.
CDT-2D4F Carbon Dioxide Transmitter, duct mount, 2000 ppm, CO2 transmitter with current/voltage CO2 outputs and 20K Ohm thermistor temperature output.
CDT-2E40 Carbon Dioxide, Wall Mount, universal current/voltage output, European Housing.
CDT-2E40-LCD Carbon Dioxide, Wall Mount, universal current/voltage output, European Housing, LCD Display.
CDT-2E44 Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, European Housing.
CDT-2E44-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, European Housing, LCD Display.
CDT-2E4A Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type III Thermistor Temperature Output, European Housing.
CDT-2E4A-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type III Thermistor Temperature Output, European Housing, LCD Display.
CDT-2E4B Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type II Thermistor Temperature Output, European Housing.
CDT-2E4B-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type II Thermistor Temperature Output, European Housing, LCD Display.
CDT-2E4C Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 3K Thermistor Temperature Output, European Housing.
CDT-2E4C-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 3K Thermistor Temperature Output, European Housing, LCD Display.
CDT-2E4D Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt100 RTD Temperature Output, European Housing.
CDT-2E4D-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt100 RTD Temperature Output, European Housing, LCD Display.
CDT-2E4E Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt1000 RTD Temperature Output, European Housing.
CDT-2E4E-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt1000 RTD Temperature Output, European Housing, LCD Display.
CDT-2E4F Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 20K Thermistor Temperature Output, European Housing.
CDT-2E4F-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 20K Thermistor Temperature Output, European Housing, LCD Display.
CDT-2N40 Carbon Dioxide, Wall Mount, universal current/voltage output, North American Housing.
CDT-2N40-LCD Carbon Dioxide, Wall Mount, universal current/voltage output, North American Housing, LCD Display.
CDT-2N44 Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, North American Housing.
CDT-2N44-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, North American Housing, LCD Display.
CDT-2N4A Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type III Thermistor Temperature Output, North American Housing.
CDT-2N4A-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type III Thermistor Temperature Output, North American Housing, LCD Display.
CDT-2N4B Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type II Thermistor Temperature Output, North American Housing.
CDT-2N4B-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 10K Type II Thermistor Temperature Output, North American Housing, LCD Display.
CDT-2N4C Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 3K Thermistor Temperature Output, North American Housing.
CDT-2N4C-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 3K Thermistor Temperature Output, North American Housing, LCD Display.
CDT-2N4D Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt100 RTD Temperature Output, North American Housing.
CDT-2N4D-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt100 RTD Temperature Output, North American Housing, LCD Display.
CDT-2N4E Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt1000 RTD Temperature Output, North American Housing.
CDT-2N4E-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, Pt1000 RTD Temperature Output, North American Housing, LCD Display.
CDT-2N4F Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 20K Thermistor Temperature Output, North American Housing.
CDT-2N4F-LCD Carbon Dioxide/Temperature, Wall Mount, universal current/voltage output, 20K Thermistor Temperature Output, North American Housing, LCD Display.
CDT-2W40 Carbon Dioxide Transmitter with universal current / voltage outputs and range 0 to 2000 PPM
CDT-2W40-LCD Carbon Dioxide Transmitter with universal current / voltage outputs and range 0 to 2000 PPM with LCD Display
CDT-2W44 Carbon Dioxide Transmitter with universal current / voltage outputs CO2 and Temperature outputs and range 0 to 2000 PPM
CDT-2W44-LCD Carbon Dioxide Transmitter with universal current / voltage outputs CO2 and Temperature outputs and range 0 to 2000 PPM with LCD Display
CDT-2W4A Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and 10K Type III NTC Thermistor Temperature Output and range 0 to 2000 PPM CO2
CDT-2W4A-LCD Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and 10K Type III NTC Thermistor Temperature Output and range 0 to 2000 PPM CO2 with LCD Display
CDT-2W4B Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and 10K Type II NTC Thermistor Temperature Output and range 0 to 2000 PPM CO2
CDT-2W4B-LCD Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and 10K Type II NTC Thermistor Temperature Output and range 0 to 2000 PPM CO2 with LCD Display
CDT-2W4D Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and Pt100 RTD Temperature Output and range 0 to 2000 PPM CO2
CDT-2W4D-LCD Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and Pt100 RTD Temperature Output and range 0 to 2000 PPM CO2
CDT-2W4E Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and Pt1000 RTD Temperature Output and range 0 to 2000 PPM CO2
CDT-2W4E-LCD Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and Pt1000 RTD Temperature Output and range 0 to 2000 PPM CO2 with LCD Display
CDT-5W40 Carbon Dioxide Transmitter with universal current / voltage CO2 outputs and range 0 to 5000 PPM CO2
CDT-5W44 Carbon Dioxide Transmitter with universal current / voltage for CO2 & temperature outputs, range 0 to 5000 PPM CO2
CDT-5W44-LCD Carbon Dioxide Transmitter with universal current / voltage for CO2 and temperature outputs, range 0 to 5000 PPM CO2 with LCD Display